Chemical-Pharmaceutical Industry

Fields of application

Manual handling
of products of any kind

Beginning with emptying of bags, up to the use of isolators designed for high dust loads..

  • Protection of operator
  • Avoidance of cross-contamination by air management
  • Explosion prevention

Application example: Barrier system connected to a self cleaning HEPA filter unit.

Product handling and dust recovery at the same OEB level. 
Containment is not broken at any time due to the wholistic technical solution. Both systems can be validated together.

Machine manufacturing of all kinds of products

Applicable for complete production lines.

Beginning from taking over the raw material, up to packaging (blistering) of the final product.

  • Protection of operator
  • Avoidance of cross-contamination by air management
  • Explosion prevention

Application example: Tablet coaters connected to self-cleaning HEPA filter units.

OEB Upgrading of Existing Production Machines

Existing production machines for the manufacture of pharmaceutical products are very often applied for higher OEB levels, than they were originally designed for. The replacement of an existing filter unit with a self-cleaning HEPA filter system, meeting the now required OEB level, is by far not enough.

Containment Technology focused its activities to engineer wholistic solutions, so that the production site can be validated anew according to the now requirements.

As a wholistic approach, we offer:

  • Upgrading of existing production machines.
  • Engineering of air management solutions.
  • Provision of additional components, such as docking systems, drum lifting devices, etc.
  • Selecting of self-cleaning HEPA filter systems according to the actual required OEB levels.
  • Provision of Filter Lifting Tables for easy fully contamination free filter change.
  • Provision of Glove Boxes or Isolators for fully contamination free dust recovery.
  • Provision of Laminar Flow Sealings as a third HEPA filter stage to protect the operator in case of recirculation of filtered air.
  • Provision of validation certificates for the self-cleaning HEPA filter system to validate the production room and the use of the filter unit at the same OEB level.

Result:

The production room, as well as the technical room, can be validated at the same OEB level required.